Showing all 14 results
Thermostatic mixing valve for eye showers
Article-No.:
BR710940
| Material | Brass |
|---|---|
| Colour | brass, black |
| Height (mm) | 136 |
| Width (mm) | 130 |
| Length/Depth (mm) | 46 |
| Weight (kg) | 0,6 |
| Adjustment range | Temperature range: 20–40°C, preset to 22°C |
| Compression stage | PN 10 |
| Differential Pressure Mixing | max. 3 bar |
| Operating pressure (bar) | max. 10,0 |
| Differential pressure between cold and hot water supply | max 0.3 bar |
| Differential pressure for activating the bypass function | at least 0.5 bar |
| Media temperature | min. 0°C / max. 95°C |
| Volume flow (l/min) | 20 liters per minute at a differential pressure of 1.0 bar |
| Air flow rate in bypass mode | 20 liters per minute at a differential pressure of 1.0 bar |
| Temperature stability | +/- 5°C (valid only if the pressure at the cold- and hot-water inlets is the same) |
| Water connections | 1/2″ male |
| Water outlet / drain | 1/2″ male |
Thermostatic mixing valve for safety showers
Article-No.:
BR710950
| Material | Brass |
|---|---|
| Colour | brass, black |
| Height (mm) | 162 |
| Width (mm) | 164 |
| Length/Depth (mm) | 56 |
| Weight (kg) | 0,6 |
| Adjustment range | Temperature range: 20–43°C, preset to 22°C |
| Compression stage | PN 10 |
| Operating pressure (bar) | max. 10,0 |
| Differential Pressure Mixing | max. 3 bar |
| Differential pressure between cold and hot water supply | max 0.3 bar |
| Differential pressure for activating the bypass function | at least 0.5 bar |
| Media temperature | min. 0°C / max. 95°C |
| Volume flow (l/min) | 110 liters per minute at a differential pressure of 2.0 bar |
| Air flow rate in bypass mode | 60 liters per minute at a differential pressure of 2.0 bar |
| Water connections | 1″ male |
| Water outlet / drain | 1″ male |
Thermostatic Mixing Valve Kit for Safety showers
Article-No.:
BR710960
| Material | Brass |
|---|---|
| Colour | brass, black |
| Height (mm) | 300 |
| Width (mm) | 290 |
| Length/Depth (mm) | 235 |
| Weight (kg) | 5,12 |
| Adjustment range | Temperature range: 20–43°C, preset to 22°C |
| Compression stage | PN 10 |
| Operating pressure (bar) | max. 10,0 |
| Differential Pressure Mixing | max. 3 bar |
| Differential pressure between cold and hot water supply | max 0.3 bar |
| Differential pressure for activating the bypass function | at least 0.5 bar |
| Media temperature | min. 0°C / max. 95°C |
| Volume flow (l/min) | 160 liters per minute at a differential pressure of 1.0 bar |
| Air flow rate in bypass mode | 90 liters per minute at a differential pressure of 1.0 bar |
| Water connections | 1 1/4″ female |
| Water outlet / drain | 1 1/4″ female |
Alarm Systems for Eye showers and Safety showers
Article-No.:
BR01580X
| Material | Polyester, glass-fiber reinforced |
|---|---|
| Height (mm) | 120 |
| Width (mm) | 122 |
| Length/Depth (mm) | 90 |
| Operating voltage | 230 V AC |
| Temperature range | -60°C to +50°C |
| Protection class | IP 66 |
| Connections | Below: 2 polyamide cable glands, black, M20x1.5 (7–13 mm); 2 polyamide cable glands, black, M16x1.5 (4.5–9 mm), On the side (left): 3 polyamide cable glands, black, M16x1.5 (4.5–9 mm) |
Alarm Systems for Eye showers and Safety showers
Article-No.:
BR01582X
| Material | Polyester, glass-fiber reinforced |
|---|---|
| Colour | black |
| Height (mm) | 120 |
| Width (mm) | 122 |
| Length/Depth (mm) | 90 |
| Temperature range | -60°C to +50°C |
| Protection class | IP 66 |
| ATEX certification | II 2G Ex eb IIC T6 Gd / II 2D Ex tb IIIC T80°C Gd |
| Connections | Below: 2 polyamide cable glands, black, M20x1.5 (7–13 mm); 2 polyamide cable glands, black, M16x1.5 (4.5–9 mm), On the side (left): 3 polyamide cable glands, black, M16x1.5 (4.5–9 mm) |
Flow monitors for eye showers and Safety showers
Article-No.:
BR7108XX
| Material | Stainless steel |
|---|---|
| Length/Depth (mm) | as shown in the Drawing / table |
| Maximum pressure | 25 bar |
| Operating pressure (bar) | max. 10,0 |
| Media temperature | min. -20°C / max. +70°C |
| Tolerance of the switching points | +/- 15% |
| Protection class | IP 65 |
| Preferred installation position | upright, horizontal |
| Inlet/outlet section | at least 5x DN |
| Direction of flow | only in one direction |
| Water connection | 1/2″ female to 1 1/4″ female |
| Water outlet / drain | 1/2″ female to 1 1/4″ female |
| Switch contact | Bistable reed switch as a normally open or normally closed contact |
| Electrical specifications | max. 2 A, max. 230 V AC/DC, max. 40 W, max. 40 VA |
| Electrical connection | 1.5-meter cable (2-wire) |
Emergency Sensor for Eye showers & Safety showers
Article-No.:
BR8304X0
| Material | Plastic, PVC |
|---|---|
| Switch output | Switch |
| Switching capacity | max. 60 W / VA |
| Switching voltage | max. 1000 mA |
| Switching time | 4.5 ms |
| Relapse time | 7.0 ms |
| Switching frequency | max. 100 Hz |
| Temperature range | -40°C to +70°C |
| Protection class | IP 67 |
| AC insulation test (rms) Ui | 1,500 V |
| Connections | PVC cable, 3 x 0.75 mm², length 3,000 mm |
Article-No.:
BR910980
Article-No.:
BR010900
Previously Viewed Products